Product details
| ITEMS/项目 | SPECIFICATION/参数 |
| Flow-rate Range/流量范围: | 0.016~100m³/h |
| Working Pressure Range/工作压力: | 0~50kPa(500mbar) |
| Relative Humidity/环境湿度: | ≤93%RH |
| Operating Temperature/工作温度: | -20°C~+50°C |
| Storage Temperature/储存温度: | -25°C~+60°C |
| Resistance/电阻: | 16±2Ω |
| Pressure Loss/压损: | ≤20Pa(6m³/h) |
| Internal Leakage/内漏: | < 0.1L/h (at1.8~15kPa) |
| Durability/使用寿命: | ≈15 Years (No Fault or Damage after Continuous Working 10000 times) |
| Operating Voltage/工作电压: | DC2.8~6.0V |
| Switching Valve Average Current /平均工作电流: | ≤80mA(DC3.6V) |
| Opening Valve Time/开阀时间: | ≤8S (DC3.6V) |
| Closing Valve Time/关阀时间: | ≤8S (DC3.6V) |
| Peak Current(Motor Start-up)/峰值电流: | ≤450mA(DC3.6V) |
| Gas Meter Application/燃气表使用: | G6~G65 Gas Meters |
| Structural Support/主要材料: | Materials are POM, Valve Seal is NBR |
| Service Fluid/工作介质: | Natural Gas/LPG |
| ATEX classification acc. To/防爆等级: | ISO EN 80079-36:2016: II 2G Ex h IIC T4 Gb |
1.该闸板阀由电机驱动机构驱动,再带动闸板实现阀门的开启/关闭。
2.该阀有两条控制线为红/黑电机线。
3.开阀过程:当黑线接“+”极,红线接“-”极时,阀门开阀,开阀时间不超8s。
4.关阀过程:当黑线接“-”极,红线接“+”极时,阀门关阀,关阀时间不超8s。
5.当在最低工作电压下开关阀门时,施加在阀门两端的电压不得超过2.5V~5.5V范围。
6.阀控回路提供的驱动电流不能小于电机峰值电流。
7.此阀门的参数及结构如有变化,我司将及时通知贵司。
免责声明:数据表仅供参考。所有数据和规格如有更改,恕不另行通知,以提高可靠性、功能、设计或其他方面。有关详细规格和具体应用支持,请随时与我们联系。